Pembaikan dan Penyelenggaraan Kilang Ultrafine Farmaseutikal

Mar 28, 2022Tinggalkan pesanan

1. Mula-mula, periksa soket kuasa, palam dan kord kuasa untuk mengesan penumpahan dan kerosakan oksigen. Jika tidak, pasangkan bekalan kuasa untuk menguji mesin.

2. Apabila motor penumbuk ultra-halus tidak berputar selepas dihidupkan-tetapi roda boleh diputar ringan dengan tangan, boleh disimpulkan bahawa salah satu daripada dua kapasitor permulaan bagi mesin gagal. Dalam kes ini, ia biasanya hanya digantikan dengan yang baru.

3. Another situation is that it does not rotate when powered on, but can rotate when external force is applied, but there is a weak current sound in the motor, which is caused by a slight leakage of the starting capacitor. If the current is too loud, the motor cannot be started at all, and it is concluded that the starting capacitor is short-circuited. In the absence of professional equipment, the capacitor can be removed first, and the two leads are inserted into the zero and live wire jacks of the mains to charge the capacitor, and then the two leads are short-circuited and discharged. If there is a discharge spark and a loud "pop" sound at this time, it means that the capacitor can be used; if the spark and the sound are weak, it means that the capacity of the capacitor has decreased, and it needs to be replaced or a small capacitor is added. If the capacitor has been damaged and short-circuited, this method cannot be used, and it must be replaced with a new product of the same specification to repair.


https://www.bolymill.com/